Leak Detection in Gas Pipeline using Hilbert-Huang Transform

N. F., Adnan and M. F., Ghazali and Makeen, Mohd Amin and A. M. A., Hamat (2015) Leak Detection in Gas Pipeline using Hilbert-Huang Transform. Applied Mechanics and Materials, 815. pp. 403-407. ISSN 1662-7482. (Published)

[img]
Preview
PDF
fkm-2015-adnan-Leak detection in gas pipeline using hilbert0001.pdf

Download (3MB) | Preview

Abstract

This paper proposes a leak detection method using acoustic. The Hamming chirp signal injected into the pipeline system and the estimation of the leak location from the delay time passing by the reflection in the pipeline if there is a leak. By using Hilbert-Huang Transform (HHT), it can give a useful signal to verify the leak. HHT transforms Empirical Mode Decomposition (EMD)and Hilbert Spectrum analysis to perform time-frequency analysis. The leak location can be detected by multiplying by the speed of sound. This simple method gives accurate leak location and easy to implement.

Item Type: Article
Uncontrolled Keywords: Leak detection, gas pipeline, HHT, Ensemble Empirical Mode Decomposition
Subjects: T Technology > TJ Mechanical engineering and machinery
Faculty/Division: Faculty of Mechanical Engineering
Depositing User: Mrs. Neng Sury Sulaiman
Date Deposited: 05 Apr 2017 04:24
Last Modified: 12 Jan 2018 02:12
URI: http://umpir.ump.edu.my/id/eprint/14575
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item