Abstract

Nanofluid is suspended of nanoparticles in a base fluid like water and lubricant oil with the purpose to increase rate of hate transfer either convection or conduction. It has been used in wide application such as in heat exchanger, automotive cooling and refrigeration system. The application of nanofluid in refrigeration system is a new approach with the purpose to increase rate of hate absorbed by evaporator. By increasing rate of heat absorbed in evaporator, the refrigeration system is able to cool down the refrigeration space faster than normal system. Currently, there are two types of approaches of nanofluid application in refrigeration system: 1) mixing with refrigerant and 2) mixing with refrigerant lubricant. Both of these approaches have no chose agreement each other and future research still in progress in this field. In order to find agreement between other researchers, this project has been conducted based on nanolubricant-refrigerant (called ‘nanolubricant’) approach. In this project Alumina and Carbon Nanotubes nanoparticles have been used in experiment. This two types of nanoparticles are selected based on study conducted by previous researchers who showed encouraging results. The nanolubricant is prepared by using 'two steps' technique which is alumina and CNT particles diluted with 'poly-ester lubricant' with concentration of 0.2%. There are three types of experiment have been conducted in this project. The first experiment is using normal lubricant which is ‘poly-ester’ lubricant, followed by experiments using CNT lubricant' and 'Alumina lubricant. The result shows that, with addition of nano particle into 'poly-ester lubricant' it increases the rate of refrigeration system performance. The maximum rate of performance improvement by adopting CNT into lubricant is 8.29%, while by using Alumina lubricant the maximum rate of performance improvement is 13.8%. As a calculation, Alumina is more suitable compared to CNT to be mixed with Ploy-ester lubricant for refrigeration system.

Item Type: Undergraduates Project Papers
Additional Information: Project paper (Bachelor of Mechanical Engineering) -- Universiti Malaysia Pahang – 2012, SV: MOHD YUSOF BIN TAIB, CD NO.: 7306
Uncontrolled Keywords: Lubrication and lubricants; Nanoparticles; Refrigeration and refrigerating machinery
Subjects: T Technology > TJ Mechanical engineering and machinery
Faculty/Division: Faculty of Mechanical Engineering
Depositing User: Mr. Nik Ahmad Nasyrun Nik Abd Malik
Date Deposited: 03 Sep 2014 02:12
Last Modified: 05 Apr 2023 03:40
URI: http://umpir.ump.edu.my/id/eprint/4961
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item