Estimation on amount of steel reinforcement for six storey hospital building with seismic design consideration in Malaysia

M. I., Adiyanto and F., Ahmad Jani and S. A. H., S. Mustapha and Saffuan, Wan Ahmad (2019) Estimation on amount of steel reinforcement for six storey hospital building with seismic design consideration in Malaysia. In: IOP Conference Series: Earth and Environmental Science, National Colloquium on Wind and Earthquake Engineering , 17-18 August 2018 , Kuantan, Pahang, Malaysia. pp. 1-7., 244 (012015). ISSN 1755-1315

[img]
Preview
Pdf
6.1 Estimation on amount of steel reinforcement for six.pdf

Download (8kB) | Preview
[img]
Preview
Pdf
4 Estimation on amount of steel reinforcement for six storey hospital.pdf
Available under License Creative Commons Attribution.

Download (919kB) | Preview

Abstract

A series of earthquakes such as Sumatra-Andaman earthquake on 26 December 2004, Nias earthquake on 28 March 2005, and Bengkulu earthquake on 12 December 2007 hadinfluences to a series of subsequence local earthquake in Peninsular Malaysia. Recently, East Malaysia especially Sabah has become earthquake prone region due to local fault. Hence, Malaysia is not totally free from seismic activities. Therefore, in 2009 Malaysian Public Work Department had concluded that it was worthwhile to consider seismic design input in new building which are located in medium to high risk earthquake zone. The effect of seismic design implementation on cost of materials has become an interesting topic to discuss. This study presents the estimation of steel reinforcement required for six storey hospital building in Malaysia with seismic design consideration. Two parameters namely as reference peak ground acceleration and class of ductility has been considered as variable. The result shows that the total amount of steel reinforcement is increased from 6%, 116%, 257%, and 290% for peak ground acceleration equal to 0.04g, 0.08g, 0.12g, and 0.16g, respectively compared to the non- seismic design counterpart. Beside, total amount of steel reinforcement is increase around 6% and 145% for ductility class medium and ductility class low, respectively compared to its non- seismic design counterpart.

Item Type: Conference or Workshop Item (Lecture)
Uncontrolled Keywords: Six storey; Design consideration
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Faculty/Division: Faculty of Civil Engineering & Earth Resources
Depositing User: Pn. Hazlinda Abd Rahman
Date Deposited: 24 Dec 2018 04:48
Last Modified: 18 Mar 2019 00:54
URI: http://umpir.ump.edu.my/id/eprint/23406
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item