UMP Institutional Repository

Effect of Excitation Frequency on Magnetic Response Induced by Frontand Back-Side Slits Measured by a Differential AMR Sensor Probe

Mohd Aufa Hadi Putera, Zaini and Mohd Mawardi, Saari and Nurul A’in, Nadzri and Aiman, Mohd Halil and Ahmad Jamil Sulaiman, Hanifah and M., Ishak (2020) Effect of Excitation Frequency on Magnetic Response Induced by Frontand Back-Side Slits Measured by a Differential AMR Sensor Probe. In: InECCE2019: Proceedings of the 5th International Conference on Electrical, Control & Computer Engineering, 29th July 2019 , Kuantan, Pahang, Malaysia. pp. 15-24., 632. ISBN 978-981-15-2317-5

[img]
Preview
Pdf
Effect of Excitation Frequency on Magnetic Response1.pdf

Download (93kB) | Preview

Abstract

Defects in steel structures are one of the major problems that may affect the functionality of the structure. Thus, the detection of the defects is fairly crucial to prevent any unwanted accident from occurring. Nondestructive Testing (NDT) is a group of methods that is widely used to detect those defects, especially cracks. This paper will be focusing on the detection of cracks (artificial slits) by using the Magnetic Flux Leakage (MFL) technique in the magnetic method of NDT. A non-saturated differential MFL probe consists of two AMR sensors has been fabricated for the detection of front as well as backside slits. A measurement system which incorporates the developed probe attached on an XY-stage, a set/reset circuit, an amplifier circuit, a DAQ card, and PC is constructed where an XY-stage controller and a digital lock-in amplifier are developed with the implementation of LabVIEW. Then, the developed MFL probe’s performance is evaluated by running several line scan measurements on a 2-mm galvanized steel plate sample engraved with artificial slits with depths that varies from 1.0 to 1.6 mm with variable excitation frequencies. The results show promising output where the slits could be successfully detected and its position could be further estimated. Furthermore, the correlation between the slit depth and difference (delta value) between the signal peaks and troughs could also be founded. Consequently, the optimum excitation frequency can be determined by plotting a graph of the slope of trend line of the delta values versus the frequency.

Item Type: Conference or Workshop Item (Lecture)
Uncontrolled Keywords: Non-destructive testing NDT Magnetic flux leakage MFL Anisotropic magnetoresistance AMR
Subjects: T Technology > T Technology (General)
T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TJ Mechanical engineering and machinery
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Faculty/Division: Faculty of Electrical & Electronic Engineering
Institute of Postgraduate Studies
Faculty of Mechanical and Automotive Engineering Technology
Depositing User: Ms. Ratna Wilis Haryati Mustapa
Date Deposited: 02 Jul 2020 08:05
Last Modified: 03 Jul 2020 03:03
URI: http://umpir.ump.edu.my/id/eprint/28631
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item