The combined cycle gas-turbine (CCGT) power plant is a highly developed technology which generates electrical power at high efficiencies. The first law of thermodynamics is used for energy analysis of the performance of the CCGT plant. The effects of varying the operating conditions (ambient temperature, compression ratio, turbine inlet temperature, isentropic compressor and turbine efficiencies, and mass flow rate of steam) on the performance of the CCGT (overall efficiency and total output power) were investigated. The programming of the performance model for CCGT was developed utilizing MATLAB software. The simulation results for CCGT show that the overall efficiency increases with increases in the compression ratio and turbine inlet temperature and with decreases in ambient temperature. The total power output increases with increases in the compression ratio, ambient temperature, and turbine inlet temperature. The peak overall efficiency was reached with a higher compression ratio and low ambient temperature. The overall efficiencies for CCGT were very high compared to the thermal efficiency of GT plants. The overall thermal efficiency of the CCGT quoted was around 57%; hence, the compression ratios, ambient temperature, turbine inlet temperature, isentropic compressor and turbine efficiencies, and mass flow rate of steam have a strong influence on the overall performance of the CCGT cycle.

Item Type:Article
Uncontrolled Keywords:Combined cycle, gas turbine, ambient temperature, compression ratio, power output, overall efficiency
Subjects:T Technology > TJ Mechanical engineering and machinery
Divisions:Automotive Engineering Centre
Faculty of Mechanical Engineering
ID Code:6853
Deposited By: Ms Suriati Mohd Adam
Deposited On:13 Jan 2015 10:29
Last Modified:09 Aug 2017 16:17

Repository Staff Only: item control page

 

 

 

 

 

 

Introduction

An Institutional Repository is an online focus for collecting, preserving, and disseminating any University publication in the digital form for the intellectual sharing.
The UMP Institutional Repository (UMP IR) provides access of University publication such as journal article, conference paper, research paper, thesis and dissertations.


Any Enquiries

Please email or call Knowledge Management staff:-

Pn. Noorul Farina (09-424 5605) OR
Cik Ratna Wilis Haryati (09-424 5612)

Any correspondence concerning this specific repository should be sent to umplibrary@ump.edu.my