Al-Shetwi, Ali Q. and Muhamad Zahim, Sujod (2016) Modeling and Ddynamics Study of Large Scale PV System Connected Malaysian Grid under Different Fault Conditions. In: International Conference on Advances in Electrical, Electronic and Systems Engineering (ICAEES) , 14-16 November 2016 , Putrajaya, Malaysia. pp. 488-494.. ISBN 978-1-5090-2889-4
PDF
fkee-2016-shetwi-modeling and dynamics study of large.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
||
|
PDF
fkee-2016-shetwi-modeling and dynamics study of large1.pdf Download (141kB) | Preview |
Abstract
The installation of photovoltaic power plants and integration with electric grid has become more widespread. Asnthere is a significant increase in the size and capacity of grid-connected power plants, the stability and reliability of the grid become more important. A 1.5 MW PV station connected to the distribution side of the Malaysian grid via a voltage source inverter is modeled and simulated using Matlab/Simulink. This study presents the modeling of PV module behavior and characteristics based on the mathematical model equivalent circuit. The Simulink was run to simulate PV array sizing depending on perturb and observed maximum power point technique to enhance the efficiency of modules, and obtain maximum available power using variable perturbation step size dependent on power changes. The simulation result was matched to the results of sizing calculation. The inverter control system modeling and park transformation were carried out. Phase locked loop was used to track the grid frequency and voltage. The Malaysian grid-connected PV system is designed and modeled according to the regulations and guidelines of Tenaga Nasional Berhad concerning grid-integration of PV power generation system to LV and MV networks. Finally, this paper analyzes the dynamic response of the proposed PV plant under various types of symmetrical and non-symmetrical grid faults. The results indicated that the short circuit faults in the distribution grid side had disturbing effects on the optimal operation performance of PV systems. Whereas, the influence of grid faults depends on the fault type. In addition to that, the simulation result proved that the symmetrical fault has higher impact on PV system operationmthan non-symmetrical faults.
Item Type: | Conference or Workshop Item (Lecture) |
---|---|
Uncontrolled Keywords: | Mathematical model, Circuit faults, Inverters, Photovoltaic systems, Integrated circuit modeling |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Faculty/Division: | Faculty of Computer System And Software Engineering Institute of Postgraduate Studies |
Depositing User: | Noorul Farina Arifin |
Date Deposited: | 24 May 2017 07:11 |
Last Modified: | 18 Oct 2019 02:40 |
URI: | http://umpir.ump.edu.my/id/eprint/17749 |
Download Statistic: | View Download Statistics |
Actions (login required)
View Item |