Abstract

Biochip is a promising device with capabilities of performing sorting, trapping and screening a large number of biological samples in a short time. Fabrication of biochip pattern process leads to an opening study towards the development of a working biochip. The traditional photolithography process have a limitation in achieving high throughput for biochip pattern fabrication. In this research, the fabrication process of biochip pattern was developed and the imprint parameter for biochip pattern using an in-house assembled plate-to-plate tool was investigated. The biochip patterns are prepared from existing projection lithography to create the mold. Using soft lithography technique, the biochip pattern was replicated invertly in the PDMS mold. The PDMS mold and in-house plate-to-plate fulfilled the requirement for UV-NIL to imprint biochip patterns on a flexible substrate. Dimension error difference (DED) is the difference between the original design dimensions to fabricated design dimensions. DED was characterized and investigated for precise pattern transfer. UV exposure of 140 W was able to produce the satisfied imprint pattern in biochip pattern mold fabrication. However, higher UV energy caused overexposure in the resist, resulting wider width and bridging. Besides that, crack regions were found when post bake exposure parameters are not properly optimized. The DED between biochip pattern mold and PDMS mold are less compared to biochip pattern mold fabrication in the photolithography process. Critical dimension in the biochip pattern was maintained in the imprint process. However, the higher imprint force will cause an overflow of the resist on the substrate, resulting unsatisfied pattern structure. The proposed parameters for imprinting biochip patterns using in-house plate-to-plate tool are 80 N range and 20 seconds of UV exposure.

Item Type: Thesis (Masters)
Additional Information: Thesis (Master of Engineering (Electronic)) -- Universiti Malaysia Pahang – 2016, SV: ASSOCIATE PROFESSOR DR. FAHMI SAMSURI, NO CD: 10761
Uncontrolled Keywords: Biochip; fabrication process
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Faculty/Division: Faculty of Electrical & Electronic Engineering
Depositing User: Ms. Nurezzatul Akmal Salleh
Date Deposited: 11 Jul 2017 08:14
Last Modified: 15 Dec 2021 00:04
URI: http://umpir.ump.edu.my/id/eprint/18147
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item