Amir Izzani, Mohamed and Takashi, Ozaki (2017) Influnce of mechanical pressure on space charge penetration behavior in low-density polyethylene (LDPE) sheet. In: 8th International Symposium On Electrical Insulating Materials , 11-15 September 2017 , Toyohashi Chamber of Commerce & Industry, Toyohashi City, Japan. pp. 1-4.. (Unpublished)
PDF
25. Influnce of mechanical pressure on space charge penetration behavior in low-density polyethylene (LDPE) sheet..pdf - Published Version Restricted to Repository staff only Download (491kB) | Request a copy |
||
|
PDF
25.1. Influnce of mechanical pressure on space charge penetration behavior in low-density polyethylene (LDPE) sheet..pdf - Published Version Download (101kB) | Preview |
Abstract
Space charge penetration into bulk of cable insulation is known as the cause of insulation breakdown thus affecting the cable power delivery capability. Penetration of packet-like positive space charge enhances local field and when the field increases up to 5 MV/cm before breakdown occurs. Exactly before the breakdown occurs, space charge penetration seems stagnant as it is prevented to penetrate further into cathode. The generated Maxwell force is assumed to press the free volume of the insulation thus reducing the size of the free volume itself the behavior of space charge under artificial pressure is discussed. A pulsed-electroacoustic (PEA) equipment capable to press the sample up to 5 ton is developed. Sample used in this study is a 150 μm low-density polyethylene (LDPE) sheet. The sample is stressed with positive dc voltage so that the mean applied field is equal to 1.5 MV/cm. The range of pressure applied to the sample is from 0 MPa and 32 MPa. The penetration gradually reduces with the increase of pressure. Sample pressed with 32 MPa show the least penetration depth as little as 5 % of the sample thickness. As a comparison, space charge penetration of sample with 0 MPa pressure is as depth as 85 % of the sample thickness. This shows that space charge penetration is restricted when sample is pressed. The result obtained shows that it need at least 24 MPa to suppress space charge penetration.
Item Type: | Conference or Workshop Item (Speech) |
---|---|
Uncontrolled Keywords: | Space charge; Low-density polyethylene; Hvdc; Transmission line |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Faculty/Division: | Faculty of Electrical & Electronic Engineering |
Depositing User: | Pn. Hazlinda Abd Rahman |
Date Deposited: | 15 Nov 2017 03:14 |
Last Modified: | 18 Apr 2018 03:57 |
URI: | http://umpir.ump.edu.my/id/eprint/18940 |
Download Statistic: | View Download Statistics |
Actions (login required)
View Item |