Al-Shetwi, Ali Q. and Muhamad Zahim, Sujod (2019) Voltage Sag Detection in Grid-Connected Photovoltaic Power Plant for Low Voltage Ride-Through Control. Recent Advances in Electrical & Electronic Engineering, 12. pp. 1-9. ISSN 2352-0973. (Published)
|
Pdf
Voltage Sag Detection in Grid-Connected1.pdf Download (176kB) | Preview |
Abstract
Background: Due to the high level of photovoltaic power plants (PVPPs) penetration into power grids, disconnections of these plants during faults are no longer possible as it may cause problems concerning stability, quality, and operation of the power system. Therefore, new grid codes have been established with low voltage ride-through (LVRT) capability standard requirements for grid-connected PVPPs that should be met. Therefore, for an efficient LVRT control, the fast and precise sag detection strategy is essential for the system to switch from normal operation to LVRT mode of operation. Methods: For this purpose, this paper presents a two automatic fault detection methods which are RMS-based (d-q) components of grid voltage and positive sequence voltage. These methods were utilized to determine the beginning and end of a voltage sag and to determine the sag depth to regulate the required reactive current that should be injected according to the LVRT standard requirements. The operating method depends on calculating present grid voltage under faults to the nominal voltage that identifies the sags’ depth and therefore inject the required amount of reactive power accordingly. Also, a comparison between the two proposed methods regarding response speed and accuracy was made. The effectiveness of these detection strategies is that it can be integrated into the voltage source inverter (VSI) without utilizing additional external hardware or software programming. Results: The simulation results demonstrated a good precision and how straightforward the proposed methods’ usage is, proving that the RMS method is faster and more accurate than positive sequence method.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Photovoltaic power plant, Sag detection, Grid faults, Low voltage-ride through, PV inverter. |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Faculty/Division: | Faculty of Electrical & Electronic Engineering Institute of Postgraduate Studies |
Depositing User: | Noorul Farina Arifin |
Date Deposited: | 25 Jan 2019 03:27 |
Last Modified: | 18 Oct 2019 02:38 |
URI: | http://umpir.ump.edu.my/id/eprint/23963 |
Download Statistic: | View Download Statistics |
Actions (login required)
View Item |