Oxygen Stripping in Deaerator Feed Water: Condensation on Spray Droplets

Click here for a simple search.
[feed] Atom [feed] RSS 1.0 [feed] RSS 2.0
 
 

K. V., Sharma and K. V., Suryanarayana and P. K., Sarma and V., Dharma Rao and T., Subramanyam (2010) Oxygen Stripping in Deaerator Feed Water: Condensation on Spray Droplets. Heat and Mass Transfer, 46 (6). pp. 665-673. ISSN 0947-7411

[img] PDF
Restricted to Repository staff only

667Kb

Official URL: http://dx.doi.org/10.1007/s00231-010-0610-x

Abstract

Deaerator is used to remove oxygen from boiler feed-water. Experiments with deaerator indicate that the droplet diameter decreases with increasing the mass flow rate of water and the increasing deaerator pressure leads to increase in heat and mass transfer coefficients. The mass transfer coefficients are found to increase with increasing the deaerator pressure, the independent of length and the oxygen concentration in inlet water.

Item Type:Article
Subjects:Q Science > QD Chemistry
T Technology > TJ Mechanical engineering and machinery
Divisions:Faculty of Mechanical Engineering
ID Code:12407
Deposited By: Ms. Nurul Amanina Lokman
Deposited On:22 Mar 2016 15:51
Last Modified:22 Mar 2016 15:51

Repository Staff Only: item control page

 

 

 

 

 

 

Introduction

An Institutional Repository is an online focus for collecting, preserving, and disseminating any University publication in the digital form for the intellectual sharing.
The UMP Institutional Repository (UMP IR) provides access of University publication such as journal article, conference paper, research paper, thesis and dissertations.


Any Enquiries

Please email or call Knowledge Management staff:-

Pn. Noorul Farina (09-424 5605) OR
Cik Ratna Wilis Haryati (09-424 5612)

Any correspondence concerning this specific repository should be sent to umplibrary@ump.edu.my