Oxygen Stripping in Deaerator Feed Water: Condensation on Spray Droplets

K. V., Sharma and K. V., Suryanarayana and P. K., Sarma and V., Dharma Rao and T., Subramanyam (2010) Oxygen Stripping in Deaerator Feed Water: Condensation on Spray Droplets. Heat and Mass Transfer, 46 (6). pp. 665-673. ISSN 0947-7411. (Published)

[img] PDF
Oxygen stripping in deaerator feed water.pdf
Restricted to Repository staff only

Download (683kB) | Request a copy

Abstract

Deaerator is used to remove oxygen from boiler feed-water. Experiments with deaerator indicate that the droplet diameter decreases with increasing the mass flow rate of water and the increasing deaerator pressure leads to increase in heat and mass transfer coefficients. The mass transfer coefficients are found to increase with increasing the deaerator pressure, the independent of length and the oxygen concentration in inlet water.

Item Type: Article
Subjects: Q Science > QD Chemistry
T Technology > TJ Mechanical engineering and machinery
Faculty/Division: Faculty of Mechanical Engineering
Depositing User: Ms. Nurul Amanina Lokman
Date Deposited: 22 Mar 2016 07:51
Last Modified: 22 Mar 2016 07:51
URI: http://umpir.ump.edu.my/id/eprint/12407
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item