The use of granular columns as soil reinforcement technique has proved useful in problems of foundation stability and settlement, as well as improving soft clay for foundation construction. The purpose of this study is to investigate the enhancement of shear strength of soft kaolin clay when it is reinforced with group crushed polypropylene (PP) columns. Since PP is a waste material, the cost of soil improvement can be reduced which currently was disposed totally in large quantity into landfill. In order to proceed the study, physical and mechanical properties of materials used that are kaolin (soil sample) and PP (reinforcing columns) must be identify first. Then, consolidated kaolin as soft clay was reinforced with group crushed PP columns, and subsequently tested under Unconfined Compression Test (UCT). A total of 7 batches of kaolin sample including control sample had been tested to identify the shear strength. Each batches involved of four samples to find the average value of maximum stress. The variables used for the columns installation were the column height that are 60 mm, 80 mm and 100 mm, where the column penetrating ratio are 0.6, 0.8 and 1.0 respectively. In addition, different values of columns diameter had been used that are 6 mm and 10 mm for every different height of columns. A total of 28 unconfined compression tests had been conducted on kaolin samples. The kaolin samples had the dimensions of 50 mm in diameter and 100 mm in height. For the group PP reinforcement, shear strength increased about 2.13%, 13.51% and 12.84% for 1.44% area replacement ratio and 6.85%, 14.26% and 13.79% for 4% area replacement ratio at sample penetration ratio 0.6, 0.8, 1.0 respectively. In the other hand, the relationship of the increment of shear strength with the various column penetration ratio show different pattern. The shear strength of both area replacement ratio increases constantly as the column penetrating ratio increased, but after it reach 80mm height of column, the shear strength decrease slightly and this support the ‘critical column length’ idea. It can be concluded that the shear strength parameters were affected by the diameter and the height of the columns and the presence of PP column greatly improve the shear strength.

Item Type: Undergraduates Project Papers
Additional Information: Undergraduates Project Papers (Bachelor of Engineering (Hons.) in Civil Engineering) - Faculty of Civil Engineering and Earth Resources - Universiti Malaysia Pahang – 2015
Uncontrolled Keywords: Soft clay reinforced; Group polypropylene columns
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Faculty/Division: Faculty of Civil Engineering & Earth Resources
Depositing User: Ms. Nurul Amanina Lokman
Date Deposited: 16 Mar 2016 07:43
Last Modified: 18 Jan 2022 03:55
URI: http://umpir.ump.edu.my/id/eprint/11943
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item