N. F., Adnan and M. F., Ghazali and Makeen, Mohd Amin and A. M. A., Hamat (2015) Leak Detection in Gas Pipeline using Hilbert-Huang Transform. Applied Mechanics and Materials, 815. pp. 403-407. ISSN 1662-7482. (Published)
|
PDF
fkm-2015-adnan-Leak detection in gas pipeline using hilbert0001.pdf Download (3MB) | Preview |
Abstract
This paper proposes a leak detection method using acoustic. The Hamming chirp signal injected into the pipeline system and the estimation of the leak location from the delay time passing by the reflection in the pipeline if there is a leak. By using Hilbert-Huang Transform (HHT), it can give a useful signal to verify the leak. HHT transforms Empirical Mode Decomposition (EMD)and Hilbert Spectrum analysis to perform time-frequency analysis. The leak location can be detected by multiplying by the speed of sound. This simple method gives accurate leak location and easy to implement.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Leak detection, gas pipeline, HHT, Ensemble Empirical Mode Decomposition |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Faculty/Division: | Faculty of Mechanical Engineering |
Depositing User: | Mrs. Neng Sury Sulaiman |
Date Deposited: | 05 Apr 2017 04:24 |
Last Modified: | 12 Jan 2018 02:12 |
URI: | http://umpir.ump.edu.my/id/eprint/14575 |
Download Statistic: | View Download Statistics |
Actions (login required)
![]() |
View Item |