The influence of ultrasonic vibration frequency on the properties of TiN coated biomedical Ti-13Zr-13Nb

Arman Shah, Abdullah and Mas Ayu, Hassan and Rosdi, Daud and Sudin, Izman and Siti Nurul Fasehah, Ismail and Che Ghani, Che Kob and Mohammed Rafiq, Abdul Kadir (2018) The influence of ultrasonic vibration frequency on the properties of TiN coated biomedical Ti-13Zr-13Nb. Metals, 8 (5). pp. 1-10. ISSN 2075-4701. (Published)

[img]
Preview
Pdf
The influence of ultrasonic vibration frequency on the properties of TiN coated biomedical Ti-13Zr-13Nb.pdf
Available under License Creative Commons Attribution.

Download (1MB) | Preview

Abstract

Bare biomedical grade titanium alloys are prone to degradation when in a body fluid environment. Surface coatings such as Physical Vapor Deposition (PVD) can serve as one of the options to minimize this issue. Past reports showed that the PVD coated layer consists of pores, pinholes, and columnar growths which act as channels through which the aggressive medium attacks the substrate. Duplex and multilayer coatings seem able to address this issue to varying extents but at the expense of manufacturing time and cost. In this paper, the effect of an ultrasonic vibration frequency on PVD TiN coated Ti-13Zr-13Nb biomedical alloy was studied. Disk type samples were prepared and coated with TiN at fixed conditions: bias voltage (− 125 V), substrate temperature (300 C), and nitrogen gas flow rate (300 standard cubic centimeters per minute (SCCM)). An ultrasonic vibration was then subsequently applied to the TiN coated samples at frequencies of 8 kHz and 16 kHz for 5 min. All TiN coated samples treated with ultrasonic vibrations exhibited a higher corrosion resistance than the untreated ones. Microstructure analysis under Field Emission Scanning Electron Microscopy (FESEM) confirmed that the coated sample at frequencies of 16 kHz produced the most compact coating.It is believed that the hammering effect of the ultrasonic vibration reduced the micro channels’ size in the coating and thus decelerated the corrosion’s attack.

Item Type: Article
Additional Information: Indexed by SCOPUS
Uncontrolled Keywords: Biomaterials; Ti–13Zr–13Nb; Ultrasonic vibration; Corrosion resistance; TiN; Titanium alloy
Subjects: T Technology > TJ Mechanical engineering and machinery
Faculty/Division: Faculty of Mechanical Engineering
Depositing User: Dr. Mas Ayu Hassan
Date Deposited: 06 Mar 2019 03:18
Last Modified: 06 Mar 2019 03:18
URI: http://umpir.ump.edu.my/id/eprint/23970
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item