Rosdi, Daud and M., Syakir and Mas Ayu, Hassan and Arman Shah, Abdullah (2019) Finite element method study: the effect of insertion torque and angle on pedicle screw loosening. In: The 4th International Conference on Frontiers of Composite Materials , 13 - 16 November 2019 , The University of Queensland, Brisbane, Australia. pp. 1-10.. (Unpublished)
Pdf
6. Finite element method study - the effect of insertion.pdf Restricted to Repository staff only Download (652kB) | Request a copy |
||
|
Pdf
6.1 Finite element method study - the effect of insertion.pdf Download (89kB) | Preview |
Abstract
Pedicle screws are widely used for the treatment of spinal instability by spine fusion. This treatment can be performed at any level in the spine (cervical, thoracic or lumbar) and prevents any movement between the fused vertebrae. However screw loosening is a major problem of spine fusion, contributing to delayed patient recovery. This appears to be a minor problem for fixation and fusion of healthy, non-osteoporotic bone. Screw loosening happen when insertion torque and angle that are not suitable for pedicle screw which affected the screw pullout strength. Based on optimum torque and angle in finite element analysis, loosening of screw in spine fusion can be minimized by increasing the screw pullout strength. The highest of pull out strength can minor the loosening of screw. Four insertion angle of pedicle screw were used which are 0°, 10°, 20° and 30°. Besides that, effect of insertion torque on pullout strength can be seen on Equivalent von Mises stress value when applied three value of moment to pedicle screw-bone with constant of insertion angle. The lowest stress for pedicle screw can give a better fixation with bone and thus can increase the pullout strength. We found that the insertion angle 10° give higher pullout strength of pedicle screw-synthetic bone which indirectly will minimizing the effect of the screw loosening from bone. Besides that, insertion torque with 1200 Nm give a lower Equivalent von Mises stress which it cause the less effect on fixation between screw and bone and thus has potential in minimizing the loosening to pedicle screw.
Item Type: | Conference or Workshop Item (Lecture) |
---|---|
Uncontrolled Keywords: | Pedicle Screw; Finite Element Analysis; Screw Loosening; Insertion Torque And Angle; Optimization |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Faculty/Division: | Faculty of Mechanical and Automotive Engineering Technology |
Depositing User: | Pn. Hazlinda Abd Rahman |
Date Deposited: | 03 Feb 2020 06:44 |
Last Modified: | 03 Feb 2020 06:44 |
URI: | http://umpir.ump.edu.my/id/eprint/27646 |
Download Statistic: | View Download Statistics |
Actions (login required)
View Item |