Kumar, Nallapaneni Manoj and Sudhakar, K. and Samykano, M. (2019) Performance evaluation of CdTe BIPV roof and façades in tropical weather conditions. Energy Sources, Part A: Recovery, Utilization, and Environmental Effects, 42 (9). pp. 1057-1071. ISSN 1556-7036 (Print); 1556-7230 (Online). (Published)
|
Pdf
Performance evaluation of CdTe BIPV roof and façades .pdf Download (541kB) | Preview |
Abstract
This study investigates the performance of thin-film cadmium telluride (CdTe) building integrated photovoltaic (BIPV) arrays (façade and roof) under tropical weather conditions in Malaysia. This investigation observed the variation in performance ratio (PR) for each façade oriented in different directions and the roof. Average annual PR for 7 kW flat roof, 2.3 kW façade in east and west, and 5.5 kW façade in north are 76.26%, 71%, 70.53%, and 66.42%, respectively, and corresponding energy losses are −23.6%, −28.8%, −29.4%, and −33.6%. It is identified that a façade oriented in north direction performs lower when compared to other façades and the roof.
Item Type: | Article |
---|---|
Additional Information: | Indexed by Scopus |
Uncontrolled Keywords: | Solar energy; Building integrated photovoltaics, BIPV façade, CdTe PV module, Performance ratio |
Subjects: | T Technology > TJ Mechanical engineering and machinery T Technology > TL Motor vehicles. Aeronautics. Astronautics |
Faculty/Division: | Faculty of Mechanical Engineering Centre of Excellence: Automotive Engineering Centre Centre of Excellence: Automotive Engineering Centre |
Depositing User: | Mrs Norsaini Abdul Samat |
Date Deposited: | 26 Jan 2021 03:38 |
Last Modified: | 26 Jan 2021 03:38 |
URI: | http://umpir.ump.edu.my/id/eprint/28473 |
Download Statistic: | View Download Statistics |
Actions (login required)
View Item |