The effects of non-uniformly-aged photovoltaic array on mismatch power loss : A practical investigation towards novel hybrid array configurations

Al Mansur, Ahmed and Amin, Md Ruhul and Hossain Lipu, Molla Shahadat and Islam, Md Imamul and Ashique, Ratil H. and Shams, Zubaeer and Haq, Mohammad Asif ul and Maruf, Md Hasan and Shihavuddin, Asm S.M. (2023) The effects of non-uniformly-aged photovoltaic array on mismatch power loss : A practical investigation towards novel hybrid array configurations. Sustainability (Switzerland), 15 (13153). pp. 1-17. ISSN 2071-1050. (Published)

[img]
Preview
Pdf
The effects of non-uniformly-aged photovoltaic array on mismatch.pdf
Available under License Creative Commons Attribution.

Download (4MB) | Preview

Abstract

One of the most important causes of a reduction in power generation in PV panels is the non-uniform aging of photovoltaic (PV) modules. The increase in the current–voltage (I–V) mismatch among the array modules is the primary cause of this kind of degradation. There have been several array configurations investigated over the years to reduce mismatch power loss (MPL) caused by shadowing, but there have not been any experimental studies that have specifically examined the impact of various hybrid array topologies taking PV module aging into consideration. This research examines the influence of the non-uniform aging scenario on the performance of solar PV modules with various interconnection strategies. Experiments have been carried out on a 4 × 10, 400 W array with 12 possible configurations, including three proposed configurations (LD-TCT, SP-LD, and LD-SP), to detect the electrical characteristics of a PV system. Finally, the performances of different module configurations are analyzed where the newly proposed configurations (SP-LD and LD-SP) show 15.80% and 15.94% higher recoverable energy (RE), respectively, than the most-adopted configuration (SP). Moreover, among the twelve configurations, the SP configuration shows the highest percentage of MPL, which is about 17.96%, whereas LD-SP shows the lowest MPL at about 4.88%.

Item Type: Article
Additional Information: Indexed by Scopus
Uncontrolled Keywords: Module rearrangement techniques; Non-uniform aging; Power loss; PV array configurations; Solar photovoltaic system
Subjects: T Technology > T Technology (General)
T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Faculty/Division: Institute of Postgraduate Studies
Faculty of Electrical and Electronic Engineering Technology
Depositing User: Mr Muhamad Firdaus Janih@Jaini
Date Deposited: 28 May 2024 08:09
Last Modified: 28 May 2024 08:09
URI: http://umpir.ump.edu.my/id/eprint/40946
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item