Effect of heating, ventilation, and air conditioning (HVAC) system on indoor air quality in a medical facility

Fauzi, Baharudin and Nur Fatt-Hiyyah, Mohd Adlan and Jalina, Kassim and Nurhidayah, Hamzah and Suriati, Ghazali (2023) Effect of heating, ventilation, and air conditioning (HVAC) system on indoor air quality in a medical facility. Journal of Sustainable Civil Engineering and Technology (JSCET), 2 (2). pp. 80-90. ISSN 2948-4294. (Published)

[img]
Preview
Pdf
Effect of Heating Ventilation and Air Conditioning.pdf

Download (543kB) | Preview

Abstract

Indoor Air Quality (IAQ) refers to the stationary air within an inhabited or occupied structure. Previously, there were fewer studies on indoor air quality in medical facilities in Malaysia especially in Terengganu. Most indoor air quality issues are caused by insufficient Heating, Ventilation, and Air Conditioning (HVAC) systems, which regulate three parameters. The purpose of this study is to assess the indoor air quality of a medical facility and determine if it complies with the Industry Code of Practice 2010 (ICOP 2010) and ASHRAE 170-2017. In this investigation, a total of 3 locations namely Administration Office, Surgical Outpatient Department (SOPD) waiting area and Ophthalmology Consultation Room in Hospital Sultanah Nur Zahirah (HSNZ) were evaluated. Walkthrough inspections were done at the locations before data collection to determine the IAQ. Two IAQ meters, notably VelociCalc and Testo, were used to collect data to assess the temperature, relative humidity, and air flow of the selected locations. Samples were taken every 2 hours for each location from 8 a.m. to 5 p.m. The data then were analysed. All three locations' temperatures were lower than ICOP 2010's acceptable limit (23-26°C), but still within ASHRAE 170-207's 21-24°C range, except for the SOPD waiting room. All three locations met ICOP 2010 and ASHRAE 170-207 relative humidity standards. Meanwhile, only the SOPD waiting room had an appropriate air flow of 0.16-0.17m/s per ICOP 2010. The study also revealed that there was a correlation between the number of occupancies and the performance of HVAC system with the indoor air quality level.

Item Type: Article
Uncontrolled Keywords: Indoor air quality; HVAC; medical facility; ICOP; ASHRAE
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TP Chemical technology
Faculty/Division: Faculty of Chemical and Process Engineering Technology
Depositing User: Mrs Norsaini Abdul Samat
Date Deposited: 18 Apr 2024 07:10
Last Modified: 18 Apr 2024 07:10
URI: http://umpir.ump.edu.my/id/eprint/40989
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item