Brain capillary geometry development for multiscale modelling study

Shabudin, Abbas and Maryah Harzarina, Jasni and Mohd Jamil, Mohamed Mokhtarudin (2022) Brain capillary geometry development for multiscale modelling study. In: IET Conference Proceedings. IET Conference Proceedings; 2022 Engineering Technology International Conference, ETIC 2022 , 07 - 08 September 2022 , Pahang, Virtual. 26 -30., 2022 (22). ISSN 2732-4494 ISBN 978-183953782-0

[img]
Preview
Pdf
Brain capillary geometry development for multiscale modelling study_ABST.pdf

Download (64kB) | Preview
[img] Pdf
Brain capillary geometry development for multiscale modelling study.pdf
Restricted to Repository staff only

Download (481kB) | Request a copy

Abstract

Due to low spatial resolution of functional magnetic resonance imaging (fMRI), mathematical modelling of human brain is usually developed in ischaemic stroke study in order to enhance the understanding of ischaemic stroke mechanism so that proper treatment plan can be decided to a particular stroke patient. A 3D brain geometry is developed in this project using AutoLISP, which is a programming language within AutoCAD. The objective of this project is to re-create the geometry developed by El-Bouri et al. by replacing the 1-dimensional line with 3-dimensional capillary which can be meshed for the simulation. Simulation of blood flow using Stokes' cell equation is done in the 3D geometry in order to obtain effective hydraulic conductivity, K. Finally, the hydraulic conductivity obtained from the simulation is analysed and compared with previous work done by El-Bouri et al. Based on result in section 3, the initial geometry developed is further modified by adding few small cylinders and also bigger volume of the geometry with 15.21% percentage difference. Non-diagonal elements obtained in matrix K show non-zero values due to small voxel size used for the simulation (180µm), which should be increased to more than 250µm. The percentage difference of diagonal elements K 11 , K 22 , and K 33 are 8.05%, 2.65% and 21.43% respectively. The large percentage differences are probably due to additional volume added to the 3D geometry to maintain its periodicity with neighbouring voxels. Besides, meshing process and mesh size chosen are also contributing factor to the large percentage difference between both hydraulic conductivity values.

Item Type: Conference or Workshop Item (Lecture)
Additional Information: Indexed by Scopus
Uncontrolled Keywords: AutoCAD; AutoLISP; Effective hydraulic conductivity; Ischaemic stroke; Microscale cell equation
Subjects: T Technology > TJ Mechanical engineering and machinery
T Technology > TS Manufactures
Faculty/Division: Institute of Postgraduate Studies
College of Engineering
Faculty of Manufacturing and Mechatronic Engineering Technology
Depositing User: Mrs Norsaini Abdul Samat
Date Deposited: 16 Jul 2024 07:33
Last Modified: 16 Jul 2024 07:33
URI: http://umpir.ump.edu.my/id/eprint/41958
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item