Optimal placement of actuator for vibration suppression based on intelligent PID controller

Muhamad Sukri, Hadi and Nadzirah, Mohd Mokhtar and Intan Zaurah, Mat Darus (2020) Optimal placement of actuator for vibration suppression based on intelligent PID controller. In: 2020 IEEE 4th International Conference on Intelligent Energy and Power Systems, IEPS 2020 - Proceedings. 4th IEEE International Conference on Intelligent Energy and Power Systems, IEPS 2020 , 7 - 11 September 2020 , Istanbul. pp. 237-241. (9263178). ISBN 978-073810568-0 (Published)

[img] Pdf
Optimal placement of actuator for vibration suppression based on.pdf
Restricted to Repository staff only

Download (978kB) | Request a copy
[img]
Preview
Pdf
Optimal placement of actuator for vibration suppression based on intelligent PID controller_ABS.pdf

Download (140kB) | Preview

Abstract

Many attempts have been proposed by the previous researchers due to reduce the undesired vibration by considering several control strategies. The simplest way in reducing the vibration is to build more rigid structure so that less vibration will be produced. Nevertheless, this strategy is usually not applicable since the structures are need high power consumption and limitation in operation speed. Furthermore, it becomes a growing trend among the industries to use light weight of mechanical structure known as flexible plate. However, the critical problem faced by the industries is vibration on the structure that can lead to structural damage. Hence, this research presents the optimal placement of actuator and sensor on the experimental rig for vibration cancelation of the flexible plate structure based on intelligent PID controller. The PID controller tuned by artificial bee colony (ABC) algorithm was used to control the undesired vibration on the structure. The robustness of developed controller was validated by varying the position of actuator on the experimental rig. It was indicated that point A2 leads to the good attenuation level by achieving highest attenuation value at the first mode of vibration with 28.83 dB which is equivalent to 21.62 % attenuation, after the introduction of vibration control.

Item Type: Conference or Workshop Item (Lecture)
Additional Information: Indexed by Scopus
Uncontrolled Keywords: Active vibration control; Artificial bee colony; Flexible plate; PID controller; Placement actuator
Subjects: T Technology > T Technology (General)
T Technology > TA Engineering (General). Civil engineering (General)
Faculty/Division: Faculty of Civil Engineering Technology
Depositing User: Mr Muhamad Firdaus Janih@Jaini
Date Deposited: 02 Dec 2024 01:13
Last Modified: 02 Dec 2024 01:13
URI: http://umpir.ump.edu.my/id/eprint/42447
Download Statistic: View Download Statistics

Actions (login required)

View Item View Item