Fatanah, M. Suhaimi and Chase, J. Geoffrey and Pretty, Christopher G. and Shaw, Geoffrey M. and Normy Norfiza, A. Razak and Ummu Kulthum, Jamaludin (2017) Insulin Sensitivity and Sepsis Score: A Correlation between Model-based Metric and Sepsis Scoring System in Critically Ill Patients. Biomedical Signal Processing and Control, 32. pp. 112-123. ISSN 1746-8094. (Published)
PDF
1-s2.0-S1746809416301008-main.pdf - Published Version Restricted to Repository staff only Download (3MB) | Request a copy |
||
|
PDF
Insulin sensitivity and sepsis score- A correlation between model-based metric and sepsis scoring system in critically ill patients 1.pdf - Published Version Download (146kB) | Preview |
Abstract
Sepsis is highly correlated with mortality and morbidity. Sepsis is a clinical condition demarcated as the existence of infection and systemic inflammatory response syndrome, SIRS. Confirmation of infection requires a blood culture test, which requires incubation, and thus results take at least 48 h for a syndrome that requires early direct treatment. Since sepsis has a strong inflammatory component, it is hypothesized that metabolic markers affected by inflammation, such as insulin sensitivity, might provide a metric for more rapid, real-time diagnosis. This study uses clinical data from 30 sepsis patients (7624 h in ICU) of whom 60% are male. Median age and median Apache II score are 63 years and 19, respectively. Model-identified insulin sensitivity (SI) profiles were obtained for each patient, and insulin sensitivity and its hourly changes were correlated with modified hourly sepsis scores (SSH1). SI profiles and values were similar across the cohort. The sepsis score is highly variable and changes rapidly. The modified hourly sepsis score, SSH1, shows a better relation with insulin sensitivity due to less fluctuation in the SIRS element. Median SI and median SI of the cohort is 0.4193e-3 and 0.004253e-3 L/mU.min, respectively. Additionally, median SI are 4.392 × 10−4 L/mU min (SSH1 = 0), 4.153 × 10−4 L/mU min (SSH1 = 1), 3.752 × 10−4 L/mU min (SSH1 = 2) and 2.353 × 10−4 L/mU min (SSH1 = 3). Significant relationship between insulin sensitivity across different SSH1 groups was observed (p < 0.05) even when corrected for multiple comparisons. CDF of SI indicates that insulin sensitivity is more significant when comparing an hourly sepsis score at a very distinguished level.
Item Type: | Article |
---|---|
Additional Information: | Indexes in Scopus. IF: 2.214 |
Uncontrolled Keywords: | Glucose-insulin model; ICU; Insulin sensitivity; Sepsis; Sepsis score |
Subjects: | Q Science > QA Mathematics R Medicine > RZ Other systems of medicine T Technology > TA Engineering (General). Civil engineering (General) T Technology > TJ Mechanical engineering and machinery |