Mohd Hazwan, Yusof and Muhammad Fadhli, Suhaimi and Mohd Hilmi, Mohd Aris and Syed Mohammad, Akhtar (2016) Numerical Study on the Effect of Geometrical Parameters on the Performance of Vortex Tube Cooling Device Using Simflow. In: International Conference on Science, Engineering, Management and Social Sciences (ICSEMSS 2016) , 6-8 October 2016 , Universiti Teknologi Malaysia. pp. 1-8..
|
PDF
328 - MOHD HAZWAN BIN YUSOF.pdf Download (337kB) | Preview |
Abstract
Vortex tube is a simple device which can separate room temperature compressed gas into the cold and hot flow. The performance of vortex tube is mainly affected by its geometrical parameters. In this study, the parameters are focused on cold outlet diameter and hot tube length. The objective of this study is to investigate the effect the cold outlet diameter and hot tube length in the range of 4-5 mm and 175-194 mm, respectively, when the inner diameter of vortex tube is 10 mm. The numerical investigation was carried using SIMFLOW 2.1 to predict the performance of vortex tube. The results show that 4 mm cold outlet diameter and 175 mm hot tube length is the optimum parameter for 10 mm inner tube diameter of the vortex tube.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Uncontrolled Keywords: | Vortex tube, Cold exit diameter, Hot tube length, SIMFLOW |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Faculty/Division: | Faculty of Mechanical Engineering |
Depositing User: | Dr. Mohd Hazwan Yusof |
Date Deposited: | 23 Mar 2017 05:42 |
Last Modified: | 19 Jan 2018 00:56 |
URI: | http://umpir.ump.edu.my/id/eprint/16222 |
Download Statistic: | View Download Statistics |
Actions (login required)
View Item |